Cementing units, or CU, are designed for pumping various fluids for cementing when drilling or overhauling, as well as during sundry flushing and overflushing operations in oil and gas wells.

These units are designed for use in mild and cold climates.

 

CEMENTING UNIT SPECIFICATIONS: BASIC CONFIGURATION

Pump unit

Triplex-plunger pump

Piston pump

Pump model

ZPN-32M

SIN-32

НПЦ-32

НЦ-320, ЦН-26-32

Useful power, kW

110

132

105

100

Plunger/piston stroke, mm

160

130

250

250

Maximum pressure, MPa

40

32 to 50

32

40

Maximum feed, dm3/s

25

16 to 25

26

26

Water supply unit

Yes/No

Measuring tank capacity, m3

5 to 6

Cementing tank capacity, m3

0,25

Manifold, nominal diameter, mm

- receiving line of the cementing pump and the centrifugal pump
- pressure line of the cementing pump and the centrifugal pump


100
50

Water supply unit

Auxiliary engine

Diesel/gasoline

Water pump

ЦНС 38-152 centrifugal pump

Rated flow, m3/s

10,5

Discharge pressure, MPa

1,54

 
 

*Technical specifications are presented on this page for reference only, as the parameters and other operational indicators depend on the vehicle configuration of choice.